Ground Flare Facilities PDF Print E-mail
Written by Administrator   
Friday, 28 May 2010 11:00

GROUND FLARE FACILITIES

groundflare

CLIENT :

PT INDOLAS PRATAMA – PERTAMINA EP REGION JAWA

PROJECT TITLE :

EPC OF HORIZONTAL GROUND FLARE FACILITIES AT TAMBUN AREA FIELD SUBANG

PROJECT DURATION : April – Oct 2007

SCOPE OF WORK :

DESIGN

FABRICATION & CONSTRUCTION

COMMISSIONING

 

Tambun Area has existing flare stack with capacity 15 MMSCFD. However this flare system has been considered to cause danger for the Pertamina personnel work inside plant (very small area), control room near the flare, and environment beside of plant (residence, agriculture plant, etc.). This is because the heat radiation, gas radiation and noise radiation because of height of stack.

Hence Pertamina EP plans to replace the existing flare stack and build new Ground Horizontal Flare at Tambun Area Field Subang capable to handling 15 MMSCFD gas relief. The flare pit numbers divided into 18 points. Around of these flare pits had been built concrete wall/fencing with height of 3m.

The overall project scope including design, procurement, fabrication and construction of flare pit, KO Drum, piping system and pipeline, pumping system, control panel, civil construction (land/ground preparation, etc.), drainage, lightning & grounding system.

 

groundflare

 

Last Updated on Friday, 28 May 2010 11:02